November 2025 Newsletter

A Word from our President

ron mcewen

by – Ron McEwen-Cold Control

Fall is in the air and Winter is right around the corner as our first hard freeze is supposed to be this weekend.  I hope clean and checks are keeping everyone busy!  We had a great turnout for our October code class. 

Next week November 11th will be our last scheduled code class for the year. Please get signed up ASAP for it. The November general meeting will be November 18th at WSU Tech and lunch will be free. Please RSVP on our website KCCAKS.com.  Remember to bring a business card to enter in the $100 drawing!

Also put Tuesday December 9th on your calendar for the KCCA Christmas party at Reddi Industries. We will have dinner, door prizes and apparently a new twist in keeping score for the Corn-hole tournament so the really good players don’t always win!!

Thank you to our vendors and Federated Insurance for supplying cash and prizes for this party.

Please remember that there will not be a general meeting in December.

Ron McEwen
Cold Control Refrigeration Inc

I look forward to seeing you throughout the year. 
Please feel free to contact me with any questions, 
Ronm@coldcontrolks.com
Office 316-942-9650


image16962792
image18278063.jpg

These awesome shirts/jerseys are available for sale…. get your orders in now.  The KCCA sponsored shirt helps support our veterans. With the assistance of one of our organizations that we help support, the B4V aka Bagging for veterans helps support our local veterans as a Cornhole organization.  All KCCA  paid members names are on the shirt/jersey. Get your own personal name on the back to make it your own. All proceeds from sales will go to support our local veterans and the B4V group. Look great in your new shirts/jersey and help our heroes at the same time. Please make sure to include the size you want( pick a size larger because they are not true to fit) and the name/ nickname you want to represent. 

Thank you all for your support!!! 

image18018778
image18018779
Tom Tallon with Alpha HVAC & Plumbing, representing our KCCA shirts during a Corn Hole tournament.

image16504694

MABCD Newsletter

Click here to get the latest updates on Mechanical, Electrical and Plumbing changes to code.


2025/2026 Meetings

image18278109.jpg

Congratulations to David Hill for winning the $500 tool scholarship. David is currently working for 1 of our current members, Cheney Electric Service, Inc. and graduated from another member WTI.

October’s General Meeting

Thank you Emily Hunter for coming to speaking to our group for a 1hr non-code credit.  We had a great turn out with 19 present and the big $100 winner was Darrell Green from WinSupply, congratulations.  

Hope to see you @ future meetings!! All general meetings are held on the 3rd Tuesday, except no meeting in July or December.


Troubleshooting Without Manual J, S, and D? You’re Flying Blind

Comfort complaints, short cycling, and airflow issues often trace back to mistakes only these measurements can expose

By Matthew Akins

image18278166
September 25, 2025

Service technicians can make a good living using their troubleshooting skills. Troubleshooting is identifying problems and establishing their cause. Effective troubleshooting demands more than just trying to match symptoms with causes. 

When it comes to HVACR troubleshooting, we naturally look for the simplest, quickest explanation — but it’s not always that simple.  

A skilled technician should recognize when the root cause of component failure is related to improper equipment sizing and airflow. At a minimum, there are three tools that service technicians should be familiar with that can help them solve some underlying issues. Those tools are ACCA Manual J, Manual D, and Manual S. First, Manual J estimates heating and cooling loads for almost all types of residential buildings. However, Manual J does not tell you which size equipment should go into the house; it only assesses the heat loss and gains on a home. Second, Manual S provides procedures for selecting and sizing residential cooling and heating equipment based on Manual J with the help of the OEM performance data. Finally, Manual D is used to design residential duct systems. Before jumping to the conclusion that incorrectly sized, selected, and ducted equipment is the culprit, do your due diligence by thoroughly inspecting the HVACR equipment.  

Manual J Let’s start with some common complaints by clients that could result from an improper load calculation. Occasionally, you may get a complaint from a customer: “It doesn’t feel comfortable to me in here. It feels hot and sticky, even though I have my a/c set to 68°.” As you know, this is just one of many complaints that may lead you to conduct a load calculation. Here are other common complaints that lead you to do a Manual J: Clients are complaining of discomfort during design weather days The client is complaining of the inability to control indoor humidity The equipment is short-cycling Repeated parts failures, such as capacitors and compressors.  It is vital to understand that Manual J is the foundation. It is the first step in diagnosing a potential issue resulting from client complaints about comfort and system performance. 

Manual S 

Next, Manual S is the procedure to ensure the home has the correctly sized equipment that will meet the sensible and latent loads of the house. Manual S emphasizes the importance of using OEM performance data that connects sensible and latent cooling capacity with the loads that affect home comfort. As with incorrect load calculations and incorrect ducting, incorrectly selected equipment has a list of issues that can arise. A home with the wrong HVACR equipment can cause: 

A home with the wrong HVACR equipment can cause: 

  • Failure to maintain indoor temperature 
  • Insufficient indoor humidity (optimum range is 40-60% RH for health and comfort) 
  • Excessive short cycling (leading to wear and tear on the equipment) 
  • Unmet sensible and latent loads at design conditions 

Not only can incorrectly sized and selected equipment lead to the above issues, but it can also contribute to health issues for the home’s occupants. For health and comfort, 50-60% RH is best. When it comes to Manual S, think of it as fitting the house for ‘shoes.’ You wouldn’t buy shoes that were too big or too small, because that would lead to sores or discomfort; you would buy shoes that fit just right. The same principle applies to selecting the correctly sized HVACR equipment for the home. 

Manual D 

Next are some common issues related to inadequate airflow and poor duct design. For example, when a duct system is not sized to handle the airflow requirement of the system efficiently, your client’s equipment may experience: 

  • Excessively loud equipment (if your client must turn the TV up when the HVAC comes on, that’s called a clue) 
  • High static pressure 
  • Premature equipment and parts failure 
  • Inadequate comfort 

When considering diagnosing and solving ducting and airflow issues, please do not use ‘rules of thumb.’ There are false ideas that the required CFM equals the floor area multiplied by some magic number or that a particular size duct always delivers a specific CFM. When in doubt, consult Manual D. If you suspect airflow/ducting issues, Manual D should be your next tool to diagnose the problem. 

When it comes to diagnosing, there are so many avenues that must be explored. However, load calculations, equipment selection, and duct designs are the foundation to ensure the home’s HVACR equipment will work correctly and efficiently. 

As a technician, you are called to work on the entire system, not an isolated part. All system components depend upon each other. In truth, it is difficult to examine any single aspect of system performance while ignoring the rest of the system. That said, the savvy technician can recognize when the equipment issues will not be resolved by throwing parts or making adjustments. Instead, they will articulate to their client the need to perform a Manual J, Manual D, and Manual S to drill down to the root cause of their issues and provide meaningful and valid remedies, not Band-Aid fixes. 

If you are not comfortable performing the Manual J, D, and S calculations, it is okay to request help and send someone to your client’s house to execute these calculations. You may want to consider reading ACCA’s ‘Bob’s House.’ ‘Bob’s House’ is a case study that discusses the residential design process from start to finish, using Bob’s house as an example. (Although it provides a comprehensive solution for this example, it does not cover every scenario or investigate every possible solution.) 

Your job as a technician is to educate your clients while at the same time being thorough and honest in your diagnosis and recommendations. Be sure to lay out all the facts so that your client can make an informed decision on how they want to proceed to remedy their HVACR system issues. 


Funny Photos

image18278224.jpeg
image18278228.jpg
image18278229.jpg

risk management corner

Every year, thousands of workplaces face the devastating impact of electrical fires. Did you know that there are an estimated 33,470 commercial electrical fires each year in the United States, killing nearly 45 people and costing around $1.36 billion in direct property damage?1
October is Fire Prevention Month, and your reminder to take action. Properly using electrical power strips and surge protectors can help reduce the chances of a fire.

Here are five simple tips that you can implement at your business today:

• Limiting the number of devices plugged into extension cords and power strips
• Removing items with lithium-ion batteries once they are charged and not charging them overnight
• Disposing of old or damaged power strips and replacing them with new ones
• Avoiding “daisy chaining” (i.e., plugging power strips into other power strips)
• Making sure that electrical cords are routed safely away from doorways and not run under rugs or carpets

If your business gets shocked by an electrical fire, your employees, family, and community could feel the burn from your doors being closed. Small steps taken today could make a real difference tomorrow.
Reach out to your local Federated Insurance® marketing representative today for more risk management resources. Federated® clients can access mySHIELD® for additional industry-specific resources.

1. Electrical Fire Protection. Firetrace International. 2025. http://www.firetrace.com/electrical-fires. Accessed August 19, 2025.